Skip to content
Demo dataset: company profiles are fictional and illustrate the product.

Company Profile

Başkent Metroloji ve Kalibrasyon

Başkent Metroloji Kalibrasyon ve Ölçüm Hizmetleri San. Tic. A.Ş.

Factory verified
DefenseAerospaceIndustrial MachineryAutomotiveRail SystemsMedical Devices

This facility was visited and verified on site. How we verify

Profile updated 15 Sept 2026Verified 20 May 2026 · valid until 20 May 2027

Machines
16
15 verified
Certifications
4
Response time
6 hours
Founded
2004
Employees
51–200
Facility
2,400 m²

Overview

About

TÜRKAK-accredited (ISO/IEC 17025) calibration laboratory for dimensional, temperature, pressure, torque and electrical quantities; contract measurement and FAI / AS9102 reporting in a 20 ± 0.5 °C metrology room with ZEISS PRISMO and CONTURA CMMs, an ATOS Q blue-light scanner, a 7-axis measuring arm and a Leica laser tracker. Defence and aerospace suppliers get per-part CMM inspection, GD&T evaluation, machine-tool geometry checks and on-site calibration.

Shown: EnglishVerified by company

Language versions

  • TurkishVerified by company
  • EnglishVerified by company
  • GermanAI translated
  • Simplified ChineseAI translated
Industries served
DefenseAerospaceIndustrial MachineryAutomotiveRail SystemsMedical Devices
Export markets
AzerbaijanKazakhstanUzbekistanGermany
Business languages
TurkishEnglishGerman
Industrial zone
İvedik OSB

Index snapshot

How it is calculated
Machine modernity
67/100
100th percentile in Quality, Testing & Metrology Services
Automation
60/100
100th percentile in Quality, Testing & Metrology Services
Certification strength
42/100
100th percentile in Quality, Testing & Metrology Services
Export readiness
70/100
100th percentile in Quality, Testing & Metrology Services

Indices are computed from profile data and are not a quality rating.

Capability matrix

Each row is a process the company performs; columns show which materials are covered and the verification level of the evidence.

  • Dimensional Metrology Service

    Carbon SteelAlloy SteelStainless SteelAluminumTitaniumInconel / Nickel AlloysPolyamide (PA / Nylon)
    Tolerance
    ±0.001 mm
    Max. part size
    1,800 × 1,200 × 1,000 mm
    Batch size
    1 – 5k
    Evidence
    7 machines as evidence
  • CMM Inspection

    Carbon SteelAluminumStainless SteelTitanium
    Tolerance
    ±0.001 mm
    Max. part size
    30,000 × 30,000 × 10,000 mm
    Evidence
    3 machines as evidence
  • 3D Scanning Inspection (Scan-to-CAD Comparison)

    AluminumCarbon SteelABSCarbon Fiber (CFRP)
    Tolerance
    ±0.01 mm
    Max. part size
    3,000 × 2,000 × 1,500 mm
    Batch size
    1 – 500
    Evidence
    2 machines as evidence
  • Dimensional Calibration (Gauges, Calipers, Micrometers, CMM)

    Tolerance
    ±0 mm
    Max. part size
    1,000 mm
    Evidence
    1 machine as evidence
  • Temperature & Humidity Calibration (Furnaces, Sensors, Chambers)

    Evidence
    1 machine as evidence
  • Electrical Calibration (Multimeters, Calibrators, Oscilloscopes, HV)

    Evidence
    1 machine as evidence
  • Pressure, Force, Torque & Mass Calibration

    Evidence
    2 machines as evidence

Legend:Factory verifiedDocument verifiedUnverified

Machine park16 machines

16 units · 15 verified · median year 2019 · 94% under 10 years · 0 with available capacity

Coordinate Measuring Machine

ZEISS PRISMO ultra 12/18/10

2021Factory verified
Measuring Accuracy (MPE)
0.9 µm
Measuring Range
1,800 mm

Calibrator / Reference Standard (Electrical, Temperature, Pressure, Length)

Fluke Calibration 9190A ultra-cool + 9173 metrology well, 1594A super-thermometer

2 units2019Factory verified

Calibrator / Reference Standard (Electrical, Temperature, Pressure, Length)

Mitutoyo 516-series steel gauge block set Grade K (112 pcs) + Mahr 826 PC comparator

2016Document verified
Measuring Range
100 mm

Calibrator / Reference Standard (Electrical, Temperature, Pressure, Length)

Fluke Calibration P3830 hydraulic + P3125 pneumatic deadweight testers

2018Factory verified

Calibrator / Reference Standard (Electrical, Temperature, Pressure, Length)

Norbar Pro-Test 1500 torque calibration analyser

2022Unverified

Coordinate Measuring Machine

ZEISS CONTURA 10/12/6 RDS

2 units2019Factory verified
Measuring Accuracy (MPE)
1.7 µm
Measuring Range
1,200 mm

Laser Tracker (Large-Volume Metrology)

Hexagon | Leica Absolute Tracker AT960-MR with T-Probe

2020Factory verified
Measuring Accuracy (MPE)
15 µm

Portable Articulated Arm CMM (with Laser Scanner)

Hexagon Absolute Arm 8525-7 with RS6 laser scanner

20227-axisFactory verified
Measuring Accuracy (MPE)
23 µm
Measuring Range
2,500 mm

3D Scanner (Structured Light / Laser)

ZEISS GOM ATOS Q 12M with ScanBox 4105

2023Factory verified

Vision / Multisensor Measuring Machine (VMM)

Mitutoyo Quick Vision Apex 302 PRO

2018Document verified
Measuring Accuracy (MPE)
1.5 µm
Measuring Range
300 mm

Surface Roughness Tester / Contour Profilometer

Mahr MarSurf XC 20 with LD 130 roughness drive

2020Document verified
Measuring Accuracy (MPE)
0.4 µm
Measuring Range
120 mm

Surface Roughness Tester / Contour Profilometer

Mitutoyo Surftest SJ-410

2 units2017Document verified
Measuring Range
25 mm

Calibrator / Reference Standard (Electrical, Temperature, Pressure, Length)

Fluke Calibration 5730A multifunction calibrator + 52120A transconductance amplifier

2021Factory verified

Products & HS codes

Product families the company supplies, with Harmonized System codes for customs and sourcing.

HS codes are indicative. Binding classification only via a BTB (Türkiye) or BTI (EU) ruling.

Trade & logistics

Exports

Yes — active exporter

Export markets

AzerbaijanKazakhstanUzbekistanGermany

Lead time

2–10 days

Payment terms

Net 30 · Advance payment for on-site calibration campaigns abroad · Annual calibration contracts invoiced quarterly (As stated by the company)

Minimum order

TRY 2,500

Foreign-trade team

1 shift

Capacity note

About 120 calibration certificates and 40 CMM reports per day; dedicated CONTURA capacity for 24-hour urgent inspection.

Logistics

Road transit to Germany: 4–6 days (indicative, by region)

Türkiye–EU Customs Union: industrial goods enter the EU duty-free with an A.TR certificate (agricultural and ECSC steel products excluded).

Lead time: from order confirmation to ex-works dispatch, unless stated otherwise.

Origin & customs guide

Export readiness

5/13

5 of 13 applicable

  • EU (DE) 0/3Missing: EU origin proof (A.TR; EUR.1 for ECSC steel); Incoterm with a named place; Coded payment terms
  • Other markets (AZ, KZ, UZ) 0/3Missing: Certificate of origin for other markets; Incoterm with a named place; Coded payment terms
  • Active exporter with named markets — Met
  • Products carry company-declared 6-digit HS codes — Not declared
  • EU origin proof (A.TR; EUR.1 for ECSC steel) — Not declared
  • Certificate of origin for other markets — Not declared
  • Incoterm with a named place — Not declared
  • Coded payment terms — Not declared
  • Sample and series lead times — Not declared
  • Minimum order value — Met
  • Named foreign-language contact — Not declared
  • Valid, verified quality certificate — Met
  • Verified capacity report — Not declared
  • Responds within 24 hours — Met
  • Profile updated within 12 months — Met

Export readiness from published data — not a certification.

Materials

Ferrous Metals

  • Carbon Steel
  • Alloy Steel
  • Stainless Steel

Non-Ferrous Metals

  • Aluminum
  • Titanium

Superalloys

  • Inconel / Nickel Alloys

Polymers

  • Polyamide (PA / Nylon)
  • ABS

Composites

  • Carbon Fiber (CFRP)

Certificates

4 current · 0 expiring within 90 days · 0 expired or inactive

Quality management

  • ISO 9001

    Quality management system

    Valid
    Certificate no.
    Not provided
    Issued by
    TSE
    Accreditation
    Accreditation not recorded
    Issued
    Not provided
    Valid until
    15 Oct 2027
    Scope
    Not provided
    Verification
    Document verified · 2 Apr 2026

Product & other

  • ISO/IEC 17025

    Testing & calibration laboratory

    Valid
    Certificate no.
    Not provided
    Issued by
    TÜRKAK
    Accreditation
    Accreditation not recorded
    Issued
    Not provided
    Valid until
    31 Mar 2029
    Scope
    Not provided
    Verification
    Factory verified · 10 Jun 2026
  • TÜRKAK

    Accreditation by the Turkish Accreditation Agency (ILAC MRA / EA MLA signatory) — scope: testing, calibration, inspection or certification

    Valid
    Certificate no.
    Not provided
    Issued by
    TÜRKAK
    Accreditation
    Accreditation not recorded
    Issued
    Not provided
    Valid until
    31 Mar 2029
    Scope
    Not provided
    Verification
    Factory verified · 10 Jun 2026
  • ISO 10012

    Measurement management system — metrological confirmation of measuring equipment

    Valid
    Certificate no.
    Not provided
    Issued by
    Not provided
    Accreditation
    Not provided
    Issued
    Not provided
    Valid until
    15 Oct 2027
    Scope
    Not provided
    Verification
    Unverified

Standard codes are shown as issued and are never translated.

Quality & inspection

Quality evidence readiness

Rates the evidence published on this profile — not the quality of parts.

42/100Partial evidence
  • Quality management system4.4 / 25
    • Best QMS certificate (tier × credit)4.4 / 25
  • Special-process approvalsNot applicable
  • Metrology11.2 / 20
    • Measuring equipment evidence8 / 8
    • Calibration records0 / 6
    • Tolerance vs. measuring capability3.2 / 6
  • Quality processes1.5 / 15
    • First article / PPAP1.5 / 5
    • Process capability (SPC)0 / 4
    • Material traceability0 / 4
    • Nonconformance handling (8D)0 / 2
  • Verification & freshness14.2 / 15
    • Company verification10 / 10
    • Machine verification4.2 / 5
  • Personnel qualificationNot applicable
How is this computed?

Certificate credit = validity × evidence × issuer legitimacy × completeness. Each component earns points; components that do not apply to this company are removed from the denominator. Score = 100 × points earned ÷ applicable points. A critical flag lowers the band by one level. Calibration records and company-declared quality-system details are not captured yet and count as not demonstrated.

Computed 14 Nov 2026

Quality flags

Computed automatically from the published data. A flag is a question to ask the supplier, not a verdict.

  • WarningNo issuing body recorded: ISO 10012

  • WarningServes Aerospace, Medical Devices without the sector quality standard (AS9100 / ISO 13485 / IATF 16949)

  • WarningTolerance tighter than 4 × the best measuring accuracy: Dimensional Metrology Service, Dimensional Calibration (Gauges, Calipers, Micrometers, CMM)

  • InfoNo certificate number for a registry lookup: ISO/IEC 17025, TÜRKAK, ISO 9001, ISO 10012

  • InfoCertificate scope not published: ISO 9001

  • InfoServes Automotive without the sector quality standard (AS9100 / ISO 13485 / IATF 16949)

  • InfoNo calibration records published for the measuring equipment

Quality system

First-article inspection
Not declared
Process capability
Not declared
Traceability
Not declared
Non-conformance handling
Not declared
NDT personnel
Not declared
Last external audit
Not declared

The company has not declared its quality system yet.

Metrology & calibration

InstrumentMeasuring volumeMPECalibrationVerification
ZEISS PRISMO ultra 12/18/10Coordinate Measuring Machine1,200 × 1,800 × 1,000 mm0.9 µmNo calibration recordFactory verified
ZEISS CONTURA 10/12/6 RDSCoordinate Measuring Machine1,000 × 1,200 × 600 mm1.7 µmNo calibration recordFactory verified
Hexagon | Leica Absolute Tracker AT960-MR with T-ProbeLaser Tracker (Large-Volume Metrology)—15 µmNo calibration recordFactory verified
Hexagon Absolute Arm 8525-7 with RS6 laser scannerPortable Articulated Arm CMM (with Laser Scanner)—23 µmNo calibration recordFactory verified
ZEISS GOM ATOS Q 12M with ScanBox 41053D Scanner (Structured Light / Laser)——No calibration recordFactory verified
Mitutoyo Quick Vision Apex 302 PROVision / Multisensor Measuring Machine (VMM)300 × 200 × 200 mm1.5 µmNo calibration recordDocument verified
Mahr MarSurf XC 20 with LD 130 roughness driveSurface Roughness Tester / Contour Profilometer—0.4 µmNo calibration recordDocument verified
Mitutoyo Surftest SJ-410Surface Roughness Tester / Contour Profilometer——No calibration recordDocument verified
  • CMM Inspection
  • 3D Optical Scanning
  • Surface Roughness Measurement
  • First Article Inspection (FAI)
  • GD&T Evaluation & Reporting (ISO 1101 / ASME Y14.5)
  • Roundness / Form Measurement
  • Contour Measurement
  • MSA (Measurement System Analysis)
  • Measurement Uncertainty Evaluation (GUM / ISO 14253)
  • Metrological Traceability (TÜBİTAK UME / PTB / NIST chain)
  • Proficiency Testing / Interlaboratory Comparison (ISO/IEC 17043)

Contact

Address

İvedik OSB, Yenimahalle, Ankara, 06378
Türkiye

Typically responds within 6 hours

Direct contact

No phone or messaging channel published. Request a quote or use the website.

Similar manufacturers

Same process: CMM Inspection

Izmir, Türkiye · Pancar Organised Industrial Zone

Manufacturer · 51–200 employees · since 2008

Factory verifiedSpeaks English
Plastic Injection MoldingCMM Inspection
Polyamide (PA / Nylon)Polycarbonate (PC)ABS+2

Exports to Germany, France, United Kingdom +1EXW/FCA15–45 d

24 machines24 verified
IATF 16949ISO 9001+2
Usually replies within 8 h

Ready to request a quote?

Başkent Metroloji ve Kalibrasyon

Send RFQ